Table 2. Evaluation results of the proposed model and [13], conducted on rendered calibration pattern images.

Without illumination correction With illumination correction
Ours [13] Ours [13]
D-Gauss PSNR ↑ 35.296 ± 3.386 9.407 ± 2.585 36.634 ± 4.329 26.546 ± 4.500
SSIM ↑ 0.979 ± 0.021 0.361 ± 0.251 0.980 ± 0.021 0.829 ± 0.181
LPIPS ↓ 0.146 ± 0.018 0.496 ± 0.301 0.143 ± 0.017 0.095 ± 0.070
Cooke PSNR ↑ 34.754 ± 3.571 8.978 ± 2.392 35.533 ± 4.262 28.101 ± 4.862
SSIM ↑ 0.973 ± 0.035 0.361 ± 0.249 0.973 ± 0.035 0.873 ± 0.174
LPIPS ↓ 0.020 ± 0.028 0.471 ± 0.304 0.020 ± 0.028 0.064 ± 0.064
Tessar PSNR ↑ 26.034 ± 5.018 8.224 ± 2.602 26.281 ± 5.218 27.185 ± 4.661
SSIM ↑ 0.805 ± 0.115 0.365 ± 0.253 0.805 ± 0.115 0.872 ± 0.166
LPIPS ↓ 0.142 ± 0.106 0.455 ± 0.289 0.141 ± 0.106 0.065 ± 0.073